Pioneers in the industry, we offer portable voc detector for industrial use model ats 101m, fixed voc gas detector model ats 105m, online voc gas detector with sampling systems model ats 105m, handheld voc meter model ats 101m, portable h2s meter and online oxygen gas purity analyzer from India.
Portable VOC Detector for industrial use Model ATS 101M
Portable VOC ( Volatile Oganic Compound) Model ATS 101M can detect the low levels of VOCs, especially in environments with strict safety regulations. Photoionization detectors (PIDs) are commonly used for broad-range VOC detection.
Specifications :-
·Accuracy : +/-2%. · Response Time; Less than 5 Sec
· Display : High quality Graphics LCD.
· Sampling : Auto Suction Sampling
· Humidity : 0-95% RH
· Span Calibration : Isobutylene Gas
· Zero Calibration: Automatic at instrument start up with fresh air sample.
· Power Supply : Lithium Rechargeable Battery
· Operating Temperature: -5 to 55deg.C
· Data logger ; 1-3600 Second User selectable
· USB Computer Interface
Applications:
Portable VOC detectors are used in various industries, including:
Model ATS -105M single channel digital control modules are designed to supervise and display the status of a single integral or remote sensor transmitter assembly. Sensor transmitter is housed in a NEMA 4X wall mount enclosure or Ex-proof enclosure. Model ATS 105M Single Channel controllers interface with industry standard two or three wire 4-20 mA sensor or other standard voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarm levels. The Graphics display can read the concentration. LEDs on the front panel provide indication of all three alarms
Request Callback
Additional Information:
Item Code: ATS105M
Production Capacity: 100
Delivery Time: One Week
Packaging Details: Gas Detector, Warranty Certificate, Calibration Certificate User Manual ETC
Yes! I am interested
Online VOC Gas Detector with Sampling Systems Model ATS 105M
Model ATS -105M single channel digital control modules are designed to supervise and display the status of a single integral or remote sensor transmitter assembly. Sensor transmitter is housed in a NEMA 4X wall mount enclosure or Ex-proof enclosure. Model ATS 105M Single Channel controllers interface with industry standard two or three wire 4-20 mA sensor or other standard voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarm levels. The Graphics display can read the concentration. LEDs on the front panel provide indication of all three alarms.
Specifications -: Sensor - PID Range - 0-2000 PPM Sampling - Auto Suction Pump Display - Graphics Display. Accuracy - ± 2% of FS & ± 0.5% of FS Alarm Setting - High and Very High Adjustable over full range
Request Callback
Additional Information:
Production Capacity: 50
Delivery Time: One Week
Packaging Details: Gas Detector, Sampling Tube & Probe, Calibration Certificate, Warranty Certificate , User Manual etc.
The ATS 101M provides the ultimate flexibility in portable detection of total volatile organic compounds (VOCs). It utilizes solid state or plug-in detector containing 10.6 eV lamp to monitor potentially hazardous compounds like Methyl Bromide, Carbon Disulfide, Hydrazine at levels as low as 10 parts per billion (PPB).
Response factors can be embedded to tune the display reading to your particular target gas or your most commonly encountered hazardous gases. Standard features include backlit LCD display, Low / High, Visual / Audible Alarm Indicator & In-built Sampling Pump, AC Adaptor / Battery Charger.
ATS 101M also offers simple auto calibration. Its available in two ranges 0 - 2000 PPB and High Range 0 - 2000 PPM High ranges can be configured up to 5000 PPM.
Gas
Sensor
Range
Resolution
VOC
PID
0-2000 PPM
1 PPM
Specifications
· Accuracy : +/-2%.
· Response Time; Less than 5 Sec
· Display : High quality Graphics LCD.
· Sampling : Auto Suction Sampling
· Humidity : 0-95% RH
· Span Calibration : Isobutylene Gas
· Zero Calibration: Automatic at instrument start up with fresh air sample.
Portable H2S Gas Meter Model ATS 101M is capable to detect H2S gas in various environment . compact light weight inteligent unit with Application specific sensor sensitive to PPM or PPB level of gases.
An online oxygen gas purity analyzer is a device used to continuously monitor and measure the concentration of oxygen (O₂) in a gas stream, ensuring that the gas meets the required purity specifications. These analyzers are typically used in industrial processes, medical applications, research, and environments where maintaining a specific oxygen level is critical.
Key Features of Online Oxygen Gas Purity Analyzers:
Real-time Monitoring: Provides continuous, real-time measurements of oxygen concentration in gases.
High Accuracy: Often use sensors like electrochemical, paramagnetic, or zirconia oxygen sensors for high precision in measuring oxygen content.
Automatic Calibration: Some systems can calibrate themselves periodically to ensure accuracy.
Data Logging: They often feature built-in data logging capabilities for tracking oxygen levels over time, which is useful for quality control, process monitoring, and compliance reporting.
Display & Alerts: Most systems include digital displays showing the O₂ concentration and can trigger alarms if oxygen levels fall outside a specified range.
Remote Monitoring: Modern systems may offer remote access for monitoring via web interfaces or SCADA systems.
Low Maintenance: While requiring periodic sensor maintenance or replacement, many systems are designed for ease of use and low maintenance.
Applications:
Industrial Gases: To ensure that oxygen used in various industrial applications (welding, chemical processes, etc.) is at the correct purity level.
Medical Applications: To monitor the purity of oxygen in medical gases supplied to patients, ensuring patient safety.
Environmental Monitoring: For measuring oxygen concentrations in environments like wastewater treatment plants or bioreactors.
Oxygen Production: Used in air separation units and other facilities where oxygen is produced and purified.
Request Callback
Additional Information:
Item Code: ATS209A
Production Capacity: 10
Delivery Time: 2 Weeks
Packaging Details: The product will be securely packaged in a Thermocal box, designed to provide thermal insulation and protection during transit. Each unit will be sealed in a protective plastic cover to prevent dust, moisture, and other contaminants from damaging the product during transport and storage. Including Calibration Certificate, Warranty Certificate & Operation Manual
Applied Techno Engineers Private Limited Gala No 104,Delta, Ind Est Bhoidapada, Bldg No 01 Vasai,East, Gokhiware, Vasai - 401208, Palghar, Maharashtra, India