Personal Oxygen Gas Monitor Applied Techno Systems portable gas detectors are marked by flexibility and quality. A variety of single or multi-gas detectors are offered in compact, lightweight designs— from simple alarm-only units to advanced, fully configurable and serviceable instruments.

Applications include underground utilities vaults, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder crews and remote fleets.


REQUEST CALLBACK
Approx. Rs 31,500 / Piece
Get Best Quote
Product Details:
Minimum Order Quantity1 Piece
UsageHospital, Personal
BrandApplied Techno Systems
ModelATS101M
We are an acclaimed name engaged in offering our precious clients a superior quality range of Oxygen Monitor for Hospital. Our offered monitor is precisely manufactured at our highly developed manufacturing unit under the direction of highly skilled professionals. Tested against different quality parameters, this monitor is broadly demanded in the market. We offer our quality-approved samplers as per the requirements of the customers at market leading prices.

Features:
  • Excellent performance
  • Reliable operation
  • Less power consumption


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 100 per month
  • Delivery Time: 1-2 Week
  • Packaging Details: Normal Packing with thermocol
Yes! I am interested
REQUEST CALLBACK
Approx. Rs 14,500 / Unit
Get Best Quote
Product Details:
Minimum Order Quantity1 Unit
Output Value4-20mA for PLC/SCADA
The ATS-109TD Sensor/Transmitter operates on 24 VDC power and features LED alarm indicators, 4-20 mA output and optional alarm relay board. This sensor/transmitter can be connected to various applied controllers or computer-based instrumentation, such as PLC or similar instrumentation.

Combustible gas Sensor/Transmitter 0-100%LEL

 

The Model ATS-109TD incorporates a pellistor or catalytic bead sensor. This sensor consists of a matched pair of elements, one active and the other for compensation. When in contact with a combustible hydrocarbon or solvent causes the gas or vapor to "burn" or oxidize at concentrations below the Lower Explosive Limit (LEL). This oxidization process raises the temperature of the active bead and increases the resistance of the internal wire coil. The second bead does not have the catalytic coating and provides compensation for environmental conditions including temperature and humidity. When these elements are connected to the circuit, a useable signal is produced that is proportional to the gas concentration.

Electrochemical Sensor/Transmitter for H2, O2, CO, H2S and other Toxic Gases

 

The ATS-109TD Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier. Gas molecules enter the cell and, as a result of an oxidation/reduction reaction, generate an electrical current proportional to the gas concentration.

NDIR Hydrocarbon Sensor/ Transmitter:

 

The ATS-109TD incorporates a sensor that operates on the NDIR principle to monitor the concentration of hydrocarbon gas. It can be calibrated for a specific gas, such as methane, but it also responds to some other hydrocarbon gases, including propane, butane, etc. The sensor features an integral semiconductor for temperature compensation, a durable tungsten filament IR light source, filter and a dual temperature-compensated pyroelectric infrared detector.

Features:

  • Detection of combustible, toxic Gases and Oxygen
  • Non-intrusive calibration
  • Smart sensors
  • Programmable relays
  • 2-wire, 3-wire, ModBus
  • Flame proof Junction Box
  • Available in stainless steel
  • Available in wireless version
  • Flame proof Junction Box Approval CCOE CMRI

Specification:
PrincipleElectrochemical, Solid State Semiconductor and Catalytic
Range%V/V, % LEL, PPM, PPB
Resolution0.1 Unit or 1 Unit (Application based)
Sampling MethodDiffusion
DisplayAlphanumeric LED
AlarmRelay Contact NO NC
Analog Output4-20mA
Digital Out PutRS 232, RS 485 and Modbus Communication Protocol
Power Source24V DC or 230VAC
Accuracy/2%
Response Time<5 Second
Sensor Life2-3 Years


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 100 per month
  • Delivery Time: 1-2 Week
  • Packaging Details: Normal Packing with thermocol
Yes! I am interested
REQUEST CALLBACK
Approx. Rs 19,300 / Piece
Get Best Quote
Product Details:
Minimum Order Quantity1 Piece
BrandApplied Techno Systems
ModelATS101M
ApplicationIndustrial, Laboratory
Portable Digital Oxygen Meter Model ATS 101M
An oxygen sensor is an electronic device that measures the proportion of oxygen (O2) in the gas or liquid being analysed.

Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 100 per month
  • Delivery Time: 1-2 Week
  • Packaging Details: Normal packing with thermocol
Yes! I am interested
 
X

Download Brochure
Applied Techno Systems

Shilpa Mankar (Marketing Manager)
104, Delta Industrial Estate, Building No. 1, Gokhivare, Sativali Road
Vasai East, Thane - 401208
Maharashtra, India
Send Email
© Applied Techno Systems. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited