Product Details:
Minimum Order Quantity | 1 Piece |
Model | ATS 208A |
Application | Industrial Use |
Brand | Applied techno Systems |
We are a well recognized name that is affianced in offering our valuable clients a world class Dust Monitor. It is precisely manufactured using best grade raw material and high-end technology in synchronization with industry standards. This is used to monitor the suspended Particulate concentration in the air with measuring range 0.001mg/M3 to 10 mg/M3. Keeping in mind the diversified requisites of our clients, it is provided in numerous technical specifications.
Features:
•Rugged design
•Smooth functioning
•Reliable operation
Applications:
•Controlled Environments
•Indoor Air Quality
•Process Control
•Mining & Ore Processing
•HVAC Application
•Emission Sourcing
•Filter Testing
•Hospitals & Clinic
Other Details:
•Optical Scattering Technology
•Graphics LCD
•Three Channel On single Window
•Suitable For PM10, PM2.5 PM1.0
•Long Life Li-ION Rechargeable battery
•Computer Interface & Data Storage
•Sampling dust and particulate matter is important as dust and particulate matter can affect the health of humans, as well as the natural environment. Dust and particulate matter can cause respiratory problems when breathed in by humans. Dust and particulates above 10 micrometer (PM10) are filtered and generally do not enter the lungs.
• Dust and particulate matter that is smaller than 10 micrometers (PM10, PM2.5, PM1.0) can enter into the Alveoli where gas exchange occurs. This PM2.5 is more dangerous as it can affect the exchange of gases within the lungs and even penetrate the lung into the blood stream and cause other health issues.
•PM10 , PM2.5 and PM1.0 are the normal sampling standards found throughout the world, they represent the particulate pollution that effects human health and thus sampling them provides an accurate insight into how dust and particulate matter effect human health.
•Handheld/Portable PM Monitor is used to monitor the suspended Particulate concentration in the air with measuring range 0.001mg/M3 to 10 mg/M3. It adopts optical scattering technique. This type of Product has many advantages, such as fast detection speed, high accuracy, light and small, easy operation, measuring and displaying of 3 channels at the same time. It adopts the method of automatic measurement, improving the work efficiency effectively.
Additional Information:
Product Details:
Application | Laboratory Use, Industrial Use |
With involvement of high-end technology, modern machinery and advanced tools in all our processes, we are engaged in offering a qualitative assortment of PM 2.5 Monitor. Our offered monitor is used to monitor the suspended Particulate concentration in the air. Our offered monitor is exceptionally valued in the market, owing to its efficient functionality and low maintenance. Clients can avail the entire array from us in various technical specifications at affordable prices.
Features:
Other Details:
Product Details:
Minimum Order Quantity | 1 Number |
measurment | Air |
Our sensor-based instruments and air quality monitoring systems Model ATS-110M are used to industrial hygienists, occupational health and safety personnel and indoor air quality professionals to assess air quality in the workplace in accordance with state and national guidelines. We provide a wide range of meters, Monitors and probes for use in indoor air quality studies to test for parameters and contaminants such as:
Handheld/Portable PM Monitor is used to monitor the suspended Particulate concentration in the air with measuring range 0.001mg/M3 to 10 mg/M3. It adopts optical scattering technique. This type of Product has many advantages, such as fast detection speed, high accuracy, light and small, easy operation, measuring and displaying of 3 channels at the same time. It adopts the method of automatic measurement, improving the work efficiency effectively.
Specifications:
Principle | Electrochemical and Light scattering |
Range | PPM/PPB or mg/M3 |
Resolution | 0.1 Unit or 1 Unit (Application based) |
Sampling Method | Diffusion, Auto Suction or Direct Plug In |
Display | 128 X 64 Graphics LCD |
Alarm | Two Levels Low & High, Visual and Audible |
Power Source | Built in Lithium Rechargeable battery |
Accuracy | /2% |
Response Time | <5 Second |
Flow Rate | 2.84 L/M |
Data Storage | 1000 or 10000 |
Sensor Life | 2-3 Years |
Operating Time | 6 – 8 hours |
Environmental | |
Temperature | 15degree Celsius |
Humidity | < 85%RH |
Atmosphere Pressure | 86- 106Kpa |
Housing | High Impact Plastic |
Dimension in mm | 130 (W) X 220 (H) X 45(D) |
Weight | 0.6 KG |
Warranty | One Year |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Model | Y09 |
Application | Chemical.& Electronic, Laboratory Use, Industrial Use |
Brand | Applied Techno Systems |
Specification:
Measuring principle | Optical scattering technology |
Light Source | Laser Diode |
Detection Range | 0.001 – 10mg/m3 |
Display | LCD |
Size Channel | PM10, PM2.5, PM1.0 |
Flow Rate | 2.83L/min (Imported Pump) |
Sample Time | 0-9999s Selectable |
Zero Count | <=10min |
Printer | External thermal printer |
Data Storage | 1000 |
Operating Time | 5 hours |
Outside Dim | 130*220*45(Wide*High*Deep) |
Weight | 0.6kg |
Environmental | |
Temperature | 15degree Celsius |
Humidity | <85%RH |
Atmosphere Pressure | 86-106Kpa |
Additional Information: